The building owner has provided no access to the roof none is required per building code and no fall protection on the roof.
Osha roof access requirements.
For example ansi standard a1264 1 1995 safety requirements for workplace floor and wall openings stairs and railing systems requires guardrail protection for the exposed sides of ladderway openings in any working walking surface.
They are present on most nonresidential buildings.
Then the roofing contractor needs to provide safe working for the roofing workers.
Here s an osha booklet on stairs and ladders.
12 16 2003 1910 23 c 1 fall protection requirements when working from ladders in the telecommunications industry 05 23 2005.
Osha requires that this distance be no greater than 3 5 feet 29 cfr 1926 502 d 16 iv but it may be less for some pfas equipment.
How far the d ring shifts and the harness stretches when it supports the full weight of a fallen worker including the weight of tool belts and other attached equipment or tools.
A stairway or ladder shall be provided at all personnel points of access where there is a break in elevation of 19 inches 48 cm or more and no ramp runway sloped embankment or personnel hoist is provided.
1910 23 c 1 additional fall protection requirements for concrete trucks when work platforms are equipped with guardrails and toeboards.
24 inches this extension above the access level must be at least 24 inches wide to accommodate the width of climber s body and not more than 30 inches of clearance allowing the climber to easily reach both hand rails.
Unprotected openings in roofs could therefore be cited under the general duty clause of the occupational safety and health act which requires an employer to provide a workplace free from recognized hazards.
When unavoidable obstructions are encountered the minimum clearance at the obstruction may be reduced to 24 inches 61 cm provided deflector plates are installed see figure d 5 of this section.
Individual rung step ladders must extend at least 42 inches 1 1 m above an access level or landing platform either by.
Through fixed ladders at their point of access egress shall have a step across distance of not less than 7 inches 18 cm nor more than 12 inches 30 cm as measured from the centerline of the steps or rungs to the nearest edge of the landing area.
Per osha 1910 23 d 4 the side rails of through or sidestep ladders must extend 42 inches above the top of the access level or landing platform served by the ladder.
Roof hatches known sometimes as roof scuttles are designed to allow workers safe access to roof areas for hvac equipment maintenance roof renovations etc.
In this case the architect would not provide anything.
Fixed ladders must be able to support at least two loads of 250 pounds 114 kg each concentrated between any two.