In the past osha has required cages for fixed ladders taller than 20 feet but as of january 2017 fall protection is required on fixed ladders taller than or that extend beyond 24 feet.
Osha roof ladder standards.
1910 25 b 1 handrails stair rail systems and guardrail systems are provided in accordance with 1910 28.
Wells must be free of projections.
1910 23 b 2 i.
Per osha 1910 23 d 4 the side rails of through or sidestep ladders must extend 42 inches above the top of the access level or landing platform served by the ladder.
Steep roof above 4 12 slope 29 cfr 1926 501 b 11.
You can choose any pfas provided it meets the osha requirements in section 1926 502 d.
Wells must completely encircle the ladder.
Ladder rungs steps and cleats are spaced not less than 10 inches 25 cm and not more than 14 inches 36 cm apart as measured between the centerlines of the rungs cleats and steps except that.
Under the new regulations a ladder over 24 feet high will require a personal fall arrest system or ladder safety system.
1910 25 b 2 vertical clearance above any stair tread to any overhead obstruction is at least 6 feet 8 inches 203 cm as measured from the leading edge of the tread.
Low slope roof 4 12 slope or less 29 cfr 1926 501 b 10.
Inside widths of wells must be at least 30 inches 76 cm.
The minimum perpendicular clearance between fixed ladder rungs cleats and steps and any obstruction behind the ladder shall be 7 inches 18 cm except in the case of an elevator pit ladder for which a minimum perpendicular clearance of 4 1 2 inches 11 cm is required.
Where this distance is less than 30 inches 0 76 m a deflection device shall be installed for guidance through the opening.
What about landing platforms.
To protect the worker exiting a ladder osha requires a 42 inch high grab bar extension above the access level or landing platform at the top of the ladder.
Bottoms of wells above the point of access.
Following osha standard strictly could leave you and your company with a liability should an accident occur.
A ladder that is less than 24 feet high does not require a fall arrest system of any sort.
Inside faces of wells on the climbing side of the ladder must extend between 27 inches 68 cm and 30 inches 76 cm.
What s changed for fixed ladder standards under osha 1910 fixed ladders provide stability when ascending to an elevated work surface because they are fastened to the building or a secure surface.
Occupational safety and health standards.